Set Up and Maintenance
152 9836 3521 01
It is possible to select if the limits for the test should be read from the spindle (default provided) or if you
want to specify your own limits. The Spindle defined limits are only displayed when ToolsTalk
PowerMACS is connected to a system.
It is possible to override the spindle configured transducer check for specific steps by using the Torque
Difference restriction.
Note! The torque diff check is not executed while the spindle functional test is performed or zero offset is
being measured. Zero offset is normally measured during the execution of a D - Diagnostic Step
but can also be done during other steps if Flying zero offset is used (see chapter: Diagnostic ).