Peripheral Devices
476 9836 3521 01
For the values spindle number, bolt number and program number the setting in the field width in the
reporter sets the number of digits to use, it is padded with 0‟s to the left to reach this number of digits. If
width is empty the actual number of digits in the result value is used.
The string sent as Maintenance Sequence is left aligned and padded with spaces to reach 30 characters.
If the total numbers of characters selected are more than 30 only the first 30 (counted from left) will be
sent. In this case an event will be issued to inform the user of the occurrence.
Example: With the following settings in the reporter:
Station name = Test1234
Spindle Number = 12
Bolt Number = 17
Program Number = 21
The maintenance sequence will be “Test12012-21”
8.11.5.3 Possible error codes
Corresponding PowerMACS error
THM, torque high monitoring
TLM, torque low monitoring
AHM, angle high monitoring
ALM, angle low monitoring
DEV1M, DEV2M or DEV, Deviation in interval 1 or 2 to high during
monitoring or Deviation to high from check. Set if any of these errors are
present.
TRH, Torque rate to high from check.
TRL, Torque rate to low from check.
TR1HM, torque rate 1 high monitoring
TR1LM, torque rate 1 low monitoring
TR2HM, torque rate 2 high monitoring
TR2LM, torque rate 2 low monitoring
TIH or TIL, time high or low from check
Also TIR, time restriction
PVTH, post view torque too high from check