2.4.3 Replacement of the System TC and Backup TC
If the System TC detects a conflict compared with the backup TC then this situation must first be resolved
before updating any other TC in the system. If the System TC detects that a backup TC with different
software version exists in the system then there is no possibility to automatically detect which TC that has
been replaced.
The solution to this is to show the above described text on both the System TC and the backup TC and let
an operator decide which TC to update.
Any other TC in the system will show the normal version conflict message as long as there is a conflict
between the System TC and the backup TC.
Note: It is not possible to download new software to the backup TC from a System TC that has no valid
setup.
2.4.4 Replacement of TC3 – TCn
If the System TC and backup TC contains the same software version and has a valid setup the System
TC continues to check for any software version conflict among TC3 – TCN. If one or several Spindle TCs
are found with a different software version the above described dialog appears on all the replaced TC. The
Spindle TC then starts to download the new software from the System TC by using functions provided by
the System TC.
Note: Since the System TC only initiates the download of new software any number of Spindle TCs could
download new software simultaneous without any interference from the System TC.
2.4.5 Updating a system with new software
As described in the previous chapter it would be possible to update a whole system with new software by
only download it to the System TC and then let the Automatic Download function update the rest of the
TCs in the system.
Note: For this to be possible the System TC must have a valid setup loaded.
2.4.6 Troubleshooting
If by any reason the download software process to any TC is interrupted by loss of power or network error
etc. then a TTPM must be used to update these TC since the Automatic Download function would not be a
part of the boot loader.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PowerMACS 4000 and is the answer not in the manual?

Atlas Copco PowerMACS 4000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPowerMACS 4000
CategoryPower Tool
LanguageEnglish

Related product manuals