Tightening
9836 3521 01 345
6.5.5 Step – Rejects
The Reject Management (RM) function is used for automatic repair of failed steps. Most of the RM
settings for a step can be found in the Rejects group.
When a failed step is detected the RM performs the following:
1. Checks bolt status
2. Decides what to do
3. Starts repair
4. If problem was correctable, continues with status OKR
5. If not correctable, terminates or continues with status NOK