Single torque transducer
If you are using the “Single run” option, run a program with a “Diagnostic” step with spindle
functional test enabled to get a new zero offset reading and compensation from the spindle.
Make at least 10 tightenings to the desired final torque and record the results from the reference
transducer (Xref) and the reported final torque from the spindle (X)
Calculate the mean reference torque (Xmeanref) and the mean final torque (Xmean).
Xmeanref = SXrefn / n where “n” is the number of tightenings
Xmean = SXn / n where “n” is the number of tightenings
Adjust the spindle parameter Scale factor for channel Torque 1 (Ts) (see Spindle Set Up,
Calibration) with the calculated value. Increase the Scale factor in order to decrease the true torque
and vice verse.
Ts-new = Ts-old x Xmeanref / Xmean
If you are using the “Single run” option, run a program with a D - Diagnostic Step in order to get a
new zero offset reading and compensation.
Run a new test series in order to confirm the correction.
If a torque scatter test is required (Standard deviation, Cp, Cpk, Cmk, CAM……) a minimum of 20
tightenings are needed.