Tightening
348 9836 3521 01
The Failure during repair alternatives are used when the station is in its Running Repair state,
that is when an error occurs during the repair.
Please note that the Retry alternative is not available for the steps located in the repair part of the
program. The steps in the repair part of the program are only intended for preparation of a repair.
CE steps do not have Failure during repair since all CE steps finishes the cycle (and thereby
ends any on-going repair).
The Failure during repair action only affects bolts that are active running repair. Bolts that are
waiting, or have finished their repair, are not affected. The following Failure during repair
alternatives are available in the main program:
Note! No Retry is allowed as Failure during repair action when steps in the repair part are run.
The Fatal failure alternatives are used when a fatal error occurs for the bolt. It offers the following
alternatives:
The Fatal failure action affects all bolts that are not already terminated. That is, also the bolts that are
waiting while other bolts are being repaired may be ordered to Terminate.