Peripheral Devices
444 9836 3521 01
MID 0401, “Automatic/Manual mode upload”
MID 0402, “Automatic/Manual mode upload acknowledge”
MID 0403, “Automatic/Manual mode unsubscribe”
MID 0410, “AutoDisable settings request”
MID 0411, “AutoDisable settings reply”
In addition to the “Automatic/Manual mode" messages the "Parameter set selected" (MID 0015) message
can be used to keep track of the stations Automatic/Manual mode state. PowerMACS sends this message
whenthe stations mode slection is changed, also when it changes to/from zero.
When entering Manual mode the following the following actions are executed internally by the
PowerMACS station:
The Open Protocol mode selection is zeroed.
The VIN number is cleared.
The station is enabled.
The OK, or batch, counter is zeroed and turned off (not used in Manual mode).
If the connection to Open Protocol is lost while in Automatic mode then the following actions are executed:
The Open Protocol mode selection is zeroed.
The station is disabled.