Peripheral Devices
9836 3521 01 479
In the Audi Variant the Master PC controls the tightening process and sends program number and start
signal to the TC over Ethernet with the XML protocol.
In the VW Variant the control of the tightening process is done over a Fieldbus interface through the
PowerMACS PLC.
If Reset MID Always is checked the MID number is always reset when an RST telegram is received from
the Master PC, otherwise it is only reset if the MID in the RST telegram is 0.
If Use only Port B is checked the Port A connection is not used. In this case the IP address of the
Application server must be set.
With No of cycle data in queue it is possible to get a queue with cycle data stored in the Audi XML device,
for cycles ran without a connection to the Master PC / Application server. The data in the queue is sent
when the connection is established. The timer Send delay for queue sets the time to wait between each
cycle data telegram. Set No of cycle data in queue to 0 if no queue is wanted.