Peripheral Devices
528 9836 3521 01
byte
PowerMACS
Input area
CC-Link master
Output
0
PLC bool AT 3000.0
Y0 (bit 0)
:
PLC bool AT 3000.1
Y1 (bit 1)
:
:
:
0
PLC bool AT 3000.7
Y7 (bit 7)
1
PLC bool AT 3001.0
Y8 (bit 8)
:
:
:
7
PLC bool AT 3007.7
Y
Data
bits
Y63 (bit 63)
8+9
PLC word AT 3008
Word 1
10+11
PLC word AT 3010
Word 2
:
:
:
22+23
PLC word AT 3022
RWw
Data
word
registers
Word 8
byte
PowerMACS
Output area
CC-Link master
Input
0
PLC bool AT 3300.0
X0 (bit 0)
:
PLC bool AT 3300.1
X1 (bit 1)
:
:
:
0
PLC bool AT 3300.7
X7 (bit 7)
1
PLC bool AT 3301.0
X8 (bit 8)
:
:
:
7
PLC bool AT 3307.7
X
Data
bits
X63 (bit 63)
8+9
PLC word AT 3308
Word 1
10+11
PLC word AT 3310
Word 2
:
:
:
22+23
PLC word AT 3322
RWr
Data
word
registers
Word 8
Two LED‟s on the AnyBus module indicate the status of the CC-Link. These LED:s can also be displayed
from the System Map form, see Indication of the fieldbus node’s for how to do this.
The function of the respective LED is as follows:
LED
Function
Indicates
1
Run
Steady off No network participation, timeout status (no power).
Steady Green Participating, normal operation.
Steady Red Major fault (FATAL error).
2
Error
Steady off No error detected (no power).
Steady Red Major fault (Exception or FATAL event).
Red, flickering CRC error (temporary flickering).
Red, flashing Station Number or Baud rate has changed since startup
(flashing)