Peripheral Devices
9836 3521 01 599
Error Proofing Ready: This signal indicates that a new cycle can begin and enables the station to start a
cycle. It is also passed through to the output Spindle Error proofing Ready (EPR), see
Interface definition output. If enabled by the parameter Flash tool light on rising EPR
signal (see chapter: GM DeviceNet) the green tool lights will start to flash when this signal
changes state from low to high. The lights will flash with an interval of 750 ms until the cycle
is completed and the result is presented.
Spindle Stop/Disable: Is used to stop the current cycle and to inactivate the spindles from any future
cycle. Must be 0 to permit a new cycle to start.
PVI number: The value of this input is added to the cycle data produced when running a cycle as the
station level result variable "Wp ID". Sampled when the Start Cycle changes from 0 to 1.
DI_GM_DisableDNetInp: This input is only available via the discrete I/O. When set to 1 all inputs via
the DeviceNet interface, except for the PVI number, are disabled.
Note! This input is always read, regardless of the value of the device parameter Through
discrete I/O (see chapter: GM DeviceNet).