EasyManua.ls Logo

Atlas Copco PowerMACS 4000

Atlas Copco PowerMACS 4000
668 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
658 9836 3521 01
5262, TC 1, Error reading reference from spindle. Ref 3, Status 50
5262, TC 1, Error reading reference from spindle. Ref 4, Status 50
5262, TC 1, Error reading reference from spindle. Ref 11, Status 50
5262, TC 1, Error reading reference from spindle. Ref 32, Status 50
5262, TC 1, Error reading reference from spindle. Ref 60, Status 50
5262, TC 1, Error reading reference from spindle. Ref 61, Status 50
5262, TC 1, Error reading reference from spindle. Ref 62, Status 50
5262, TC 1, Error reading reference from spindle. Ref 63, Status 50
5262, TC 1, Error reading reference from spindle. Ref 64, Status 50
5262, TC 1, Error reading reference from spindle. Ref 65, Status 50
5262, TC 1, Error reading reference from spindle. Ref 89, Status 50
5262, TC 1, Error reading reference from spindle. Ref 90, Status 50
5262, TC 1, Error reading reference from spindle. Ref 100, Status 50
5262, TC 1, Error reading reference from spindle. Ref 109, Status 50
5262, TC 1, Error reading reference from spindle. Ref 170, Status 50
5262, TC 1, Error writing reference to spindle. Ref 62, Status 21
after which the Box is programmed with default values.
When the Box is programmed all parameters that are important for controlling the spindle, including the
calibration parameters, are set. However, the following parameters are left unchanged:
The serial number of the spindle
The total number of cycles run
The total number of cycles run at last service
The date when the last service was made
The value of these parameters can be set, at any time, using the new "Service Data" page of the TTPM
Spindle Set Up form when on-line to a spindle of Conversion Box type.

Table of Contents

Related product manuals