Basic Functions
94 9836 3521 01
Use the check boxes in the top of the form to select variables to present in the list. If e.g. the SPC
checkbox is marked the list will include SPC variables, otherwise not.
It is also possible to drag & drop variables from the Dynamic Tool to the three variable list boxes.
The Settings property grid shows the settings for the currently selected variable.
Check this checkbox to include the variable name as a leading, or prompter, text. When using
table layout (Header text frequency > 0) then the variable name is always used as column header
regardless of the selection in this column.
Specifies the number of decimals to print. Only valid for variables of numerical type and when
format is Printable (Data/Printable selected).
Defines the width of the field, in number of characters, in which the value of the variable is
printed. (left adjusted).
When using table layout (Header text frequency > 0) then the width must be big enough to cover
the variable name since it is used as column header.
When format is binary (Data/Binary selected) then Width normally should be left blank for all
numerical values variables. This will cause the selection in the Type column to control the width of
the field. However, specifying a value that is larger than the number of bytes implicated by the
Type selection will make the variable occupy the specified number of bytes. Data is then left
adjusted (the field is padded with NULL (0) characters).