SmartROC D65 Tier 4 Final 14 Options
216
n The RC tubes are removed and replaced with normal drill pipes. The air swivel is re-
moved and replaced with an adapter. The deflectors and sample hose can be re-
moved. An adapter is fitted on the rotation head for the air supply to the drill string.
This is a longer-term adaptation and is used if normal drilling is to be carried out over
several weeks or more.
14.4 Fire suppression system
14.4.1 Daily checks and maintenance
If there is a pressure gauge fitted, then check that the needle on the pressure meter for the
containers is within the green zone.
On semi-automatic fire fighting systems, check that the LEDs are working as specified
in the Operator's Manual. Perform a test - press the green test button (7) for at least 1
second. The diodes come on successively and conclude with an alarm test of signal and
lamp.
14.4.2 Annual maintenance
In many countries, insurance companies require proof that a qualified engineer has inspec-
ted and approved the fire fighting system annually. We recommend checking with your in-
surance company to find out if they have any requirements concerning this system.
14.4.3 Electric Welding, Steam Cleaning and High Pressure Cleaning
CAUTION
Risk of injury
The operator's panel on semi-automatic fire fighting systems must be disabled for the
following tasks:
u Electric welding, battery charging and start help. Harmful currents can damage the
electronics.
u Steam cleaning. The heat detectors are triggered at 120°C and could be activated by
the steam.
u High-pressure washing. Components or cables could be damaged by the jets and trig-
ger the system.
Once the semi-automatic fire fighting system is enabled again, make sure the LEDs and
the system work as specified in the Operator's Manual. Perform a test - press the green
test button on the operator's panel for at least 1 second. The diodes come on successively
and conclude with an alarm test of signal and lamp. A description of the operator's panel
can be found in the Operator's Manual
14.5 Service Winch
14.5.1 Cleaning
Always clean the winch after use.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco SMARTROC D65 TIER 4 FINAL and is the answer not in the manual?

Atlas Copco SMARTROC D65 TIER 4 FINAL Specifications

General IconGeneral
BrandAtlas Copco
ModelSMARTROC D65 TIER 4 FINAL
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals