EasyManuals Logo

Atlas Copco SMARTROC D65 TIER 4 FINAL User Manual

Atlas Copco SMARTROC D65 TIER 4 FINAL
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
SmartROC D65 Tier 4 Final 4 Hardware RCS
40
4.1.2 Pin configurations
Contact Type Pin 1 Pin 2 Pin 3 Pin 4 Pin 5
X1 Four-pin
M12, male
contact
+24V supply
voltage
+24V supply
voltage
GND GND
X2, X3, X4 Five-pin
M12, male
contact (X2,
X4) or fe-
male contact
(X3)
NC (Not
Connected)
CAN +24V CAN GND CAN Hi CAN
X5 Five-pin
M12, male
contact
Bit 2 Bit 1 GND Bit 0 Bit 3
Each address bit is connected to GND (ground). The address plug can be connected
to four different addresses.
4.1.3 LED functions
Module status (D16)
n LED colour is green.
n When the system starts the LED flashes twice per second.
n When CAN communication is in progress the LED will flash once per second.
n When there is no CAN communication or if the I/O module is starting up the LED will
flash five times per second.
CAN status network 1 (D14) and network 2 (D15)
n LED colour is red.
n The LED flashes when communication is established.
n Black LED means no communication.
Supply voltage CAN network 1 (D19) and CAN network 2 (D20)
n LED colour is green.
n Fixed green glow means supply voltage maintained.
n Black LED means no supply voltage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco SMARTROC D65 TIER 4 FINAL and is the answer not in the manual?

Atlas Copco SMARTROC D65 TIER 4 FINAL Specifications

General IconGeneral
BrandAtlas Copco
ModelSMARTROC D65 TIER 4 FINAL
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals