SmartROC D65 Tier 4 Final 11 Diesel engine
164
!
NOTE: NOTE! If the safety cartridge has also been removed for
changing, the filter housing air outlet must be completely covered
with adhesive tape before cleaning the filter housing.
4.
Check that the evacuation valve (4) is not damaged. Change it if necessary.
5.
Remove any adhesive tape there may be on filter housing air outlet.
6.
Install a new main cartridge and a new safety cartridge if required.
7.
Refit the cover and fasten the clamps.
Checking the indicator
To ensure filter clogging is detected, the function of the indicator (6) must be checked regu-
larly. This is done by gradually blocking the air intake with a piece of wood or similar. The
indicator should then signal and the warning symbol should be visible, or the warning light
should illuminate. If the warning does not indicate, start by checking the cable connections.
If there are no problems with the connections, then the indicator is faulty and must be re-
placed.
!
NOTE: The indicator is not included in the filter housing, but is ordered separately.
Take care to use a whole and clean piece of wood so that dirt or other particles do not
enter the filter housing.
11.4.3 Fuel system
Fuel quality
See the chapter Oils and fuel.
Filter
There are two types of fuel filter for the diesel engine, a primary filter and two secondary fil-
ters.
The diesel engine fuel filter must be changed and not cleaned.