CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Trap Varbinds
Trap varbinds are sent with each proprietary SNMP trap. Refer to the AcBoard MIB for more
information on these varbinds.
Table 7-1: Trap Varbinds for Proprietary SNMP Traps
Trap Varbind Description
acBoardTrapGlobalsName (1) Alarm or event number. The number value is
obtained from the last digit(s) of the OID of
the sent trap, and then subtracted by 1. For
example, for the trap
acBoardEthernetLinkAlarm, which has an OID
of 1.3.6.1.4.1.5003.9.10.1.21.2.0.10, the value
of the varbind is 9 (i.e., 10 1).
The value is an integer from 0 to 1000.
acBoardTrapGlobalsTextualDescription
(2)
Description of the reported issue.
The value is an octet string of up to 200
characters.
acBoardTrapGlobalsSource (3) The source of the issue. For example, Trunk#1
or Entity1#x.
The value is an octet string of up to 100
characters.
acBoardTrapGlobalsSeverity (4) Active alarm severity on the device:
noAlarm(0)
indeterminate(1)
warning(2)
minor(3)
major(4)
critical(5)
AcBoardTrapGlobalsUniqID (5) Consecutive number count of trap since
device was powered on. The number is
managed separately for alarms and events.
For example, you may have an alarm whose
value is 1 and an event whose value is 1.
The value is an integer from 0 to 32000.
acBoardTrapGlobalsType (6)
other(0)
- 92 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals