CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Probable
Cause
transmitFailure
Severity Condition Text Corrective Action
Critical RAI "Trunk RAI Alarm" Make sure that
transmission is correct.
Cleared End of RAI - -
DS1 Line Status Alarm
The alarm is applicable only to digital PSTN interfaces.
Table 7-7: dsx1LineStatusChange
Alarm dsx1LineStatusChange
OID 1.3.6.1.2.1.10.18.15.0.1
Default
Severity
Major on raise; Clear on clear
Source
Varbind
Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being the
first trunk
Event
Type
communicationsAlarm
Probable
Cause
Severity Text Additional Info1,2,3
- DS1 Line Status Updated DS1 Line Status.
This variable indicates the Line Status of the interface. It
contains loopback, failure, received 'alarm' and
transmitted 'alarms' information.
dsx1LineStatus is a bitmap represented as a sum, so it can
represent multiple failures (alarms) and a LoopbackState
simultaneously.
dsx1NoAlarm must be set if and only if no other flag is set.
If the dsx1loopbackState bit is set, the loopback in effect
can be determined from the dsx1loopbackConfig object.
The various bit positions are:
- 101 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C