CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acgwAdminStateChange
changed
to
shutting
down
Gateway is shutting down.
No time limit."
■ A network administrator
took an action to
gracefully lock the device.
Major Admin
state
changed
to locked
"Locked"
■ No corrective action is
required.
■ A network administrator
took an action to lock the
device, or a graceful lock
timeout occurred.
Cleared Admin
state
changed
to
unlocked
-
■ No corrective action is
required.
■ A network administrator
has taken an action to
unlock the device.
Operational Status Change Alarm
Table 7-25: acOperationalStateChange
Alarm acOperationalStateChange
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.15
Description The alarm is sent if the operational state of the node changes to
disabled. It is cleared when the operational state of the node changes
to enabled.
Default Severity Major
Event Type processingErrorAlarm
Probable Cause outOfService (71)
Severity Condition Text Corrective Action
Major Operational
state changed
to disabled
"Network
element
operational state
change alarm.
Operational state
is disabled."
■ The alarm is cleared when
the operational state of the
node changes to enabled.
■ In IP systems, check for
initialization errors - in IP
systems the operational
- 125 -