CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acBoardConfigurationError
Critical A configuration
error was
detected
"Board Config
Error: A run-time
specific string
describing the
configuration
error"
a. Check the run-
time specific
string to determ-
ine the nature of
the configuration
error.
b. Fix the con-
figuration error
using the appro-
priate tool: Web
interface, OVOC,
or ini file.
c. Save the con-
figuration and if
necessary reset
the device.
Note: The alarm remains
in Critical severity until a
device reboot. A Clear
trap is not sent.
After
configuration
error
-
Software Reset Alarm
Table 7-18: acBoardEvResettingBoard
Alarm acBoardEvResettingBoard
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.5
Description The alarm is sent after the device resets.
Default
Severity
Critical
Event Type equipmentAlarm
Probable
Cause
outOfService (71)
Severity Condition Text Corrective Action
Critical When the device is
reset through the
"Device is
resetting"
A network administrator has reset
the device. Corrective action is not
- 116 -