EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #148 background imageLoading...
Page #148 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acCloudLicenseManagerAlarm
The device couldnt initialize
connection with OVOC
(handshake).
"Device was
rejected by
OVOC while
trying to
fetch device
id"
<Forbidden 403>: Contact
AudioCodes support.
Cleared
Connection with OVOC is
established.
Reports are sent
successfully.
Floating License or Flex
License is disabled on the
device or the device is
removed from the Fixed
License Pool on OVOC.
The alarm is cleared upon
the next device reset.
- -
Floating License Alarm
The alarm is applicable only to the Flex License and Floating License.
Table 7-35: acFloatingLicenseAlarm
Alarm acFloatingLicenseAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.138
Description The alarm is sent when insufficient memory resources (physical
memory) exist for the capacity of the user-defined (Custom)
Allocation Profile configured for the Floating License on the Floating
License page.
Source Varbind
Text
Board#1
Event Type processingErrorAlarm
Additional Info Detailed explanation of the problematic parameter, requested and
actual value. For example: "SignalingSessions requested 10000,
allocated 1000"
- 139 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing