EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
HA Ethernet Group Alarm
Table 7-15: acHAEthernetGroupAlarm
Alarm acHAEthernetGroupAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.137
Description The alarm is sent when the Ethernet link of at least one port in the
Ethernet Group that is associated with the HA Maintenance
interface is down.
Default Severity Minor
Source Varbind Text system#0
Event Type qualityOfServiceAlarm
Probable Cause outOfService
Severity Condition Text Corrective Action
Minor At least one of the
Ethernet port links
in the Ethernet
Group associated
with the HA
Maintenance
interface is down
"SYS_HA:
Maintenance
Group - One of the
links is down - NO
HA of maintenance
link redundancy"
Check that the
Ethernet cables are
connected securely
to the ports. Check
that the ports at the
other end are up
(working).
Cleared All Ethernet ports in
the Ethernet Group
associated with the
HA Maintenance
interface become
up again
- -
Board Alarms
The source varbind text for all alarms under this component is System#0<n>, where n is the
slot number in which the blade resides in the chassis.
- 114 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals