EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Cleared alarm:
CLEAR-ALARM: <Alarm Name>; Textual Description: <Textual Description>; Severity <Alarm
Severity>; Source <Alarm Source>; Unique ID: <Alarm Unique ID >; If exists Additional
Info1:/ Additional Info2:/ Additional Info3:
SNMP Alarms
The tables in the following subsections provide information on alarms triggered as a result of a
generated SNMP trap. The component name (described in each of the following headings)
refers to the string provided in the acBoardTrapGlobalsSource trap varbind. To clear a
generated alarm, the same notification type is sent but with the severity set to Cleared’.
You can customize the severity level of SNMP trap alarms using the Alarms
Customization table [AlarmSeverity]. This table also lets you suppress alarms.
Trunk Alarms
This section describes the SNMP alarms concerned with digital trunk interfaces.
Trunk Near-End LOS Alarm
Table 7-3: acTrunksAlarmNearEndLOS
Alarm acTrunksAlarmNearEndLOS
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.49
Default
Severity
Critical
Source
Varbind
Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being
the first trunk
Event
Type
communicationsAlarm
Probable
Cause
lossOfSignal
Severity Condition Text Corrective Action
Critical Near-end LOS "Trunk LOS
Alarm"
Loss of Signal (LOS) indicates a physical
problem.
1. Check that the cable is connected
on the board.
- 98 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing