CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm dsx1LineStatusChange
1dsx1NoAlarmNo alarm present
2dsx1RcvFarEndLOFFar end LOF (a.k.a., Yellow Alarm)
4dsx1XmtFarEndLOFNear end sending LOF Indication
8dsx1RcvAISFar end sending AIS
16dsx1XmtAISNear end sending AIS
32dsx1LossOfFrameNear end LOF (a.k.a., Red Alarm)
64dsx1LossOfSignalNear end Loss Of Signal
128dsx1LoopbackStateNear end is looped
256dsx1T16AISE1 TS16 AIS
512dsx1RcvFarEndLOMFFar End Sending TS16 LOMF
1024dsx1XmtFarEndLOMFNear End Sending TS16
LOMF
2048dsx1RcvTestCodeNear End detects a test code
4096dsx1OtherFailureAny line status not defined
here
8192dsx1UnavailSigStateNear End in Unavailable Signal
State
16384dsx1NetEquipOOSCarrier Equipment Out of
Service
32768dsx1RcvPayloadAISDS2 Payload AIS
65536dsx1Ds2PerfThresholdDS2 Performance
Threshold Exceeded
B-Channel Alarm
The alarm is applicable only to digital PSTN interfaces.
Table 7-8: acBChannelAlarm
Alarm acBChannelAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.85
Default
Severity
Minor
Source
Varbind
Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being the
first trunk
Event communicationsAlarm
- 102 -