CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acDChannelStatus
Alarm. D-
Channel is
Out Of
Service"
Minor NFAS D-channel (primary or backup) goes down
(fails)
"D-
Channel
Alarm.
Primary
NFAS D-
Channel is
Out Of
Service"
or
"D-
Channel
Alarm.
Backup
NFAS D-
Channel is
Out Of
Service"
-
Cleared ISDN D-channel is re-established. "D-
Channel
Alarm. %s"
-
NFAS Group Alarm
Table 7-10: acNFASGroupAlarm
Alarm acNFASGroupAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.84
Default Severity Major
Source Varbind Text Interfaces#0/Trunk#<m>, where m is the trunk interface number,
1 being the first trunk
Event Type communicationsAlarm
Probable Cause degradedSignal