CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acBoardEthernetLinkAlarm
the no HA
alarm that
follows such a
case.
Ethernet Group Alarm
Table 7-38: acEthernetGroupAlarm
Alarm acEthernetGroupAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.86
Description The alarm is sent when an Ethernet port in an Ethernet Group goes
down.
Note: If an Ethernet Group is configured with two ports and only one
port goes down, the alarm is not sent.
Default Severity Major
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable
Alarm Text Ethernet Group alarm. %s
Severity Condition Text
Corrective
Action
Major Ethernet Group is configured
with only one port and the port
is down.
"Ethernet Group
alarm. Ethernet
Group <ID> is
Down"
-
Major Ethernet Group is configured
with two ports and both ports
are down.
"Ethernet Group
alarm. Ethernet
Group (ID> is
Down"
-
Cleared Ethernet Group configured with
only one port: alarm cleared
when the port comes up again.
Ethernet Group configured with
two ports: alarm is cleared
when at least one port comes
- -
- 143 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing