CHAPTER4 Topology MIB Objects
Mediant 800 SBC | SNMP Reference Guide
ifTable & ifXTable Value
ifHCInOctets
ifHCOutOctets
64-bit versions of counters. Required for ethernet-like
interfaces that are capable of operating at 20 Mb/s or
faster, even if the interface is currently operating at less
than 20 Mb/s.
ifHCInUcastPkts
ifHCInMulticastPkts
ifHCInBroadcastPkts
ifHCOutUcastPkts
ifHCOutMulticastPkts
ifHCOutBroadcastPkts
64-bit versions of packet counters. Required for ethernet-
like interfaces that are capable of operating at 640 Mb/s or
faster, even if the interface is currently operating at less
than 640 Mb/s.
Therefore, will be constant zero.
ifLinkUpDownTrapEnable Set to disabled (2). Refer to [RFC 2863].
ifPromiscuousMode Constant False. [R/O]
ifConnectorPresent Constant True.
ifAlias An 'alias' name for the interface as specified by a network
manager (NVM)
ifCounterDiscontinuityTime As defined in IfMIB.
DS1 Interface
The DS1 interface is applicable only to digital PSTN interfaces.
Table 4-2: DS1 Digital Interface
ifTable Value
ifDescr Digital DS1 interface.
ifType ds1(18).
ifMtu Constant zero.
ifSpeed DS1 = 1544000, or E1 = 2048000, according to dsx1LineType
ifPhysAddress The value of the Circuit Identifier [dsx1CircuitIdentifier]. If
no Circuit Identifier has been assigned this object should
have an octet string with zero length.
ifAdminStatus Trunks Lock & Unlock during run time. In initialization
- 23 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing