EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #176 background imageLoading...
Page #176 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Event acHitlessUpdateStatus
parameter."
"Hitless fail:
SW ver
stream name
too long."
Hitless Upgrade failed because the cmp
file is invalid. The number of characters
defining the software version stream
name in the cmp file has been
exceeded.
Replace the cmp file with a
valid one
"Hitless fail:
Invalid cmp
file - missing
UPG
parameter."
Hitless Upgrade failed because the cmp
file is invalid. An upgrade parameter is
missing from the file.
Replace the cmp file with a
valid one.
"Hitless fail:
Hitless SW
upgrade not
supported."
Hitless Upgrade failed because the cmp
file is invalid. The cmp file does not
support Hitless Upgrade of the current
software version to the new software
version.
Replace the cmp file with a
valid one that supports hitless
upgrade of the software from
the current version to the
new one.
Secure Shell (SSH) Connection Status Trap
Table 7-66: acSSHConnectionStatus
Event acSSHConnectionStatus
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.77
Default
Severity
indeterminate
Event Type environmentalAlarm
Probable
Cause
other
Alarm Text
"SSH logout from IP address <IP>, user <user>"
"SSH successful login from IP address <IP>, user <user> at:
<IP>:<port>"
"SSH unsuccessful login attempt from IP address <IP>, user <user> at:
<IP>:<port>. <reason>"
"WEB: Unsuccessful login attempt from <IP> at <IP>:<port>. <reason>"
Status
- 167 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals