EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Event acProxyConnectivity
connected to this same proxy,
check if there are more Audi-
oCodes devices with the same trap
event. If this is the case, this could
confirm that this is not an issue
with the device.
4. Contact AudioCodes support and
send a syslog and network capture
for this issue.
Cleared When
connection
to the
proxy is
available
again
"Proxy Server
<IP
address>:<port>
is now IN
SERVICE"
-
Cold Start Trap
Table 7-68: coldStart
Event ColdStart
OID 1.3.6.1.6.3.1.1.5.1
MIB SNMPv2-MIB
Description The alarm is sent if the device reinitializes following, for example, a power
failure, crash, or CLI reload command. Categorized by the RFC as a
“generic trap”.
Note This is a trap from the standard SNMP MIB.
Authentication Failure Trap
Table 7-69: authenticationFailure
Event authenticationFailure
OID 1.3.6.1.6.3.1.1.5.5
MIB SNMPv2-MIB
Description The alarm is sent if a device is sampled with an incorrect community name,
- 169 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing