CHAPTER2 SNMP Overview
Mediant 800 SBC | SNMP Reference Guide
A detailed explanation of each parameter can be viewed in the MIB Description
field.
A detailed description in HTML format of all MIBs can be found in the MIBs
directory (included in the Release package).
Not all groups in the MIB are implemented.
MIB Objects that are marked as 'obsolete' are not implemented.
When a parameter is Set to a new value via SNMP, the change may affect device
functionality immediately or may require that the device be soft reset for the
change to take effect. This depends on the parameter type.
The current (updated) device configuration parameters are configured on the device
provided the user doesn't load an ini file to the device after reset. Loading an ini file
after reset overrides the updated parameters.
SNMP Interface Details
This subsection describes details of the SNMP interface needed when developing an Element
Management System (EMS) for any AudioCodes devices, or to manage a device with a MIB
browser.
There are several alternatives for SNMP security:
SNMPv2c community strings
SNMPv3 User-based Security Model (USM) users
SNMP encoded over IPSec
Various combinations of the above
Currently, both SNMP and ini file commands and downloads are not encrypted. For ini file
encoding, refer to the device's User's Manual.
SNMP Community Names
By default, the device uses a single, read-only community string of "public" and a single read-
write community string of "private". Up to five read-only community strings and up to five
read-write community strings, and a single trap community string can be configured. Each
community string must be associated with one of the following predefined groups:
Table 2-1: SNMP Predefined Groups
Group Get Access Set Access Sends Traps
ReadGroup Yes No Yes
ReadWriteGroup Yes Yes Yes
TrapGroup No No Yes
- 8 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing