EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acMediaRealmBWThresholdAlarm
Type
Probable
Cause
The alarm is sent when a bandwidth threshold is crossed
Severity Condition Text Corrective Action
Major - "Media Realm BW
Threshold Alarm"
Cleared when bandwidth threshold
returns to normal range
Call Quality Alarms
This section describes the alarms concerned with call quality.
Answer-Seizure Ratio Threshold Alarm
Table 7-51: acASRThresholdAlarm
Alarm acASRThresholdAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.111
Description The Answer-Seizure Ratio (ASR) measures the percentage of answered calls
relative to the total number of attempted calls (seizures). The alarm is sent
when the configured ASR minor and major thresholds are crossed
(configured in the Performance Profile table).
Source
Varbind
Text
The object for which the threshold is crossed can be any of the following:
PM_gwSBCASR
PM_gwSBCIPGroupASR
PM_gwSBCSRDASR
Alarm Text -
Event Type QualityOfServiceAlarm
Probable
Cause
ThresholdCrossed
Severity Condition Text Corrective Action
Major ASR is equal or less than
the configured Major
threshold.
"ASR threshold
crossed."
-
- 153 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals