CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acLicensePoolOverAllocationAlarm
supported by the
device.
(Sent after the
configuration has
been applied in
the License Pool;
but prior to a
device reset or
hitless upgrade.)
capability and will
not be applied”
upgrade); the device sets
its SBC capacity to
maximum and disregards
the excess configured
sessions.
Reconfigure the license
sessions with values that
fall within the device
capacity and then apply the
new license (reset device or
apply hitless upgrade).
Warning The SBC license
received from the
License Pool has
exceeded the
maximum capacity
supported by the
device.
(Sent after a
device restart.)
“License Pool
Alarm. Some of
the license pool
allocations will not
be used because
of over-allocation
In the OVOC License Pool,
reconfigure the license
sessions with values that fall
within the device capacity and
then apply the new license
(reset device or apply hitless
upgrade).
License Pool Infrastructure Alarm
The alarm is applicable only to the Fixed License.
Table 7-32: acLicensePoolInfraAlarm
Alarm acLicensePoolInfraAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.106
Description The alarm is sent if one of the following occurs:
The device is unable to communicate with the OVOC License
Pool.
The device license has expired.
The device is no longer managed by the OVOC License Pool.
Default Severity Major
Source Varbind system0Mo
- 133 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing