CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acOperationalStateChange
state of the node is
disabled if the device fails
to properly initialize.
Look for other alarms and
Syslogs that might provide
additional information
about the error.
Cleared Operational
state changed
to enabled
- -
Remote Monitoring Alarm
Table 7-26: acRemoteMonitoringAlarm
Alarm acRemoteMonitoringAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.145
Description The alarm is sent when the device loses connection with the remote
monitoring server (configured on the device as a Remote Web Service) for
remote monitoring of the device when it is located behind a NAT.
Default
Severity
Warning
Source
Varbind
Text
Board#1
Event Type communicationsAlarm
Probable
Cause
callEstablishmentError
Alarm
Severity
Condition Text Corrective Action
Warning The device receives an HTTP
failure response
(4xx/5xx/6xx) when it sends
the monitoring report.
"No connection
with Remote
Monitoring server"
Check that the
configuration of the
Remote Web
Service is correct.
Cleared The device receives an HTTP - -
- 126 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing