CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acBoardControllerFailureAlarm
Failure in a Serving IP
Group for the trunk
"BusyOut Trunk n
Serving IP Group
Failure"
Where n represents
the BRI / PRI trunk ID.
-
FXO physical port is
down
"BusyOut Line n Link
failure"
Where n represents
the FXO port number
(0 for the first port).
Verify that the FXO
line is securely cabled
to the device's FXO
port.
BRI or PRI physical port
is down
"BusyOut Trunk n Link
failure"
Where n represents
the BRI / PRI trunk
port number (0 for the
first port).
Verify that the digital
trunk is securely
cabled to the device's
digital port.
Cleared Proxy is found. The
'Cleared' message
includes the IP address
of this Proxy.
- -
Board Overload Alarm
Table 7-23: acBoardOverloadAlarm
Alarm acBoardOverloadAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.11
Description The alarm is sent when there is an overload in one or some of the system's
components. An overload occurs when a specific percentage of CPU
resources is available. You can configure the percentage of available
resources to trigger the raising of this alarm, by using the CLI command
configure voip > sip-definition settings >
overload-sensitivity-level.
Default
Severity
Major
Event Type processingErrorAlarm
- 123 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing