CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acASRThresholdAlarm
Minor ASR is equal or less than
the configured Minor
threshold (but greater
than the Major
threshold).
"ASR threshold
crossed."
-
Cleared ASR is above the
configured Minor
threshold plus the
hysteresis.
- -
Average Call Duration Threshold Alarm
Table 7-52: acACDThresholdAlarm
Alarm acACDThresholdAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.112
Description The Average Call Duration (ACD) plus the SDD (Session Disconnect
time) measures the average call duration from the time from when
the sip Bye is sent to the time when the 200 OK is received. The alarm
is sent when the configured ACD minor and major thresholds are
crossed (configured in the Performance Profile table).
Source Varbind
Text
The object for which the threshold is crossed can be any one of the
following:
PM_gwSBCACD
PM_gwSBCIPGroupACD
PM_gwSBCSRDACD
Alarm Text
Event Type Quality Of Service Alarm
Probable Cause The threshold has been crossed.
Severity Condition Text Corrective Action
Major ACD is equal or less
than the configured
Major threshold.
"ACD threshold
crossed."
-
Minor ACD is equal or less - -
- 154 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing