CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acNFASGroupAlarm
Severity Condition Text Corrective Action
Major An NFAS
group goes
out-of-
service
"NFAS Group
Alarm. %s"
The alarm is sent only
when the backup Non-
Facility Associated
Signaling (NFAS) D-channel
also falls, i.e., when both
D-channels are down.
When at least one of the
D-channels (primary or
backup) returns to service,
the alarm is cleared.
Corrective action is not
necessary.
Clear NFAS group
state goes to
in- service
"%s– Additional
information"
-
High-Availability Alarms
This section describes the alarms concerned with the High Availability (HA) system.
HA System Fault Alarm
Table 7-11: acHASystemFaultAlarm
Alarm acHASystemFaultAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.33
Description The alarm is sent when the High Availability (HA) system is faulty (i.e.,
no HA functionality).
Default Severity Critical
Source Varbind
Text
System#0/Module#<m>, where m is the blade module’s slot number
Event Type qualityOfServiceAlarm
Probable Cause outOfService
Severity Condition Text Corrective Action
- 105 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals