CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acNFASGroupAlarm
Severity Condition Text Corrective Action
Major An NFAS
group goes
out-of-
service
"NFAS Group
Alarm. %s"
■ The alarm is sent only
when the backup Non-
Facility Associated
Signaling (NFAS) D-channel
also falls, i.e., when both
D-channels are down.
■ When at least one of the
D-channels (primary or
backup) returns to service,
the alarm is cleared.
■ Corrective action is not
necessary.
Clear NFAS group
state goes to
in- service
"%s– Additional
information"
-
High-Availability Alarms
This section describes the alarms concerned with the High Availability (HA) system.
HA System Fault Alarm
Table 7-11: acHASystemFaultAlarm
Alarm acHASystemFaultAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.33
Description The alarm is sent when the High Availability (HA) system is faulty (i.e.,
no HA functionality).
Default Severity Critical
Source Varbind
Text
System#0/Module#<m>, where m is the blade module’s slot number
Event Type qualityOfServiceAlarm
Probable Cause outOfService
Severity Condition Text Corrective Action