CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Event authenticationFailure
access permission or incorrectly authenticated protocol message.
Categorized by the RFC as an “enterprise-specific trap”.
Board Initialization Completed Trap
This is the AudioCodes Enterprise application cold start trap.
Table 7-70: acBoardEvBoardStarted
Event acBoardEvBoardStarted
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.4
Description The alarm is sent after the device is successfully restored and initialized
following reset.
MIB AcBoard
Severity cleared
Event Type equipmentAlarm
Probable
Cause
Other(0)
Alarm Text Initialization Ended
Configuration Change Trap
Table 7-71: entConfigChange
Event entConfigChange
OID 1.3.6.1.2.1.4.7.2
MIB ENTITY-MIB
Description The alarm is sent if a change in the device's hardware is detected, for
example, when a module is removed from the chassis.
- 170 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing