CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acCertificateExpiryAlarm
certificate of
TLS context
%d will expire
in a day"
Or
"The TLS
certificate of
TLS context
%d will expire
in less than a
day"
Critical The certificate has expired. "The
certificate of
TLS context
%d has
expired %d
days ago"
Load a new certificate to
the device before the
expiration of the installed
certificate (which cannot be
renewed automatically).
To replace certificates, refer
to the User's Manual.
Cleared A new certificate is
installed.
-
License Key Alarms
This section describes the alarms concerned with the device's License Key.
Feature Key Error Alarm
The alarm is applicable only to the local License Key.
Table 7-28: acFeatureKeyError
Alarm acFeatureKeyError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.6
Description The alarm is sent when an error occurs in the local License
Key.
Default Severity Critical
Source Varbind Text
- 128 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals