CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Event acHTTPDownloadResult
Description The alarm is sent upon success or failure of the HTTP Download action.
Default
Severity
Indeterminate
Event Type processingErrorAlarm (3) for failures and other (0) for success.
Probable
Cause
other (0)
Status
Changes
Condition Successful HTTP download.
Trap Text HTTP Download successful
Condition Failed download.
Trap Text HTTP download failed, a network error occurred.
Note There are other possible textual messages describing NFS failures or
success, FTP failure or success.
Dial Plan File Replaced Trap
The trap event is applicable only to analog and digital interfaces.
Table 7-63: acDialPlanFileReplaced
Event acDialPlanFileReplaced
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.45
Default Severity Indeterminate
Event Type Other (0)
Probable Cause Other (0)
Status Change
Condition Successful dial plan file replacement
Trap Text "Dial plan file replacement complete."
- 164 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing