CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acProxyConnectionLost
the proxy set
are offline"
All proxy servers were offline
and now at least one proxy
server in the Proxy Set is
online (and at least one
proxy server is still offline)
"Proxy Set <ID>
("<Name>"):
Server <IP
address>:<port>
is up, one or
more servers in
the proxy set
are still offline"
Cleared All proxy servers in the Proxy
Set are online
"Proxy found.
ip:<IP
address>:<port
#> Proxy Set ID
<ID>"
-
Controller Failure Alarm
Table 7-22: acBoardControllerFailureAlarm
Alarm acBoardControllerFailureAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.9
Description The alarm is sent in the following scenarios:
Physical FXO port is up or down (Out-of-Service or OOS). The FXO line
can be down due to, for example, port disconnected or insufficient
current and voltage. (Syslog message event is ANALOG_IF_LINE_
DISCONNECTED.)
Physical BRI or PRI (E1/T1) port is up or down (OOS).
Proxy is not found or registration fails. In such a case, the device's
routing table may be used for routing instead of the Proxy.
Connection to the Proxy is up or down.
Failure in TDM-over-IP call - transparent E1/T1 without signalling.
Connection to the Proxy Set associated with the trunk/line is up/down.
Failure in server registration for the trunk/line.
Failure in a Serving IP Group for the trunk.
Failure in a Proxy Set.
- 121 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C