EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acFeatureKeyError
Event Type processingErrorAlarm
Probable Cause configurationOrCustomizationError (7)
Alarm Severity Condition Text Corrective Action
Critical License Key
error.
"Feature key
error"
-
License Key Hitless Upgrade Alarm
The alarm is applicable only to the local License Key.
Table 7-29: acLicenseKeyHitlessUpgradeAlarm
Alarm acLicenseKeyHitlessUpgradeAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.129
Description The alarm is sent when installing a local License Key using the Hitless
Upgrade method when the device operates in High-Availability (HA)
mode, and installation fails due to a failure in the HA switchover
process.
Default Severity Major
Source Varbind
Text
system0Mo
Event Type communicationsAlarm
Probable Cause keyExpired
Alarm Severity Condition Text Corrective Action
Major License Key Hitless
Upgrade failed due
to failure in HA
switchover process.
"Feature key hitless
upgrade failed due
to failure of
switchover process"
Reload the License
Key, and then
perform the Hitless
Upgrade process.
License Pool Application Alarm
The alarm is applicable only to the Fixed License.
- 129 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing