CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Fatal Error Alarm
Table 7-16: acBoardFatalError
Alarm acBoardFatalError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.1
Description The alarm is sent whenever a fatal device error occurs.
Default Severity Critical
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable (56)
Severity Condition Text Corrective Action
Critical Any fatal
error
"Board Fatal Error: A
run-time specific
string describing the
fatal error"
1. Capture the alarm inform-
ation and the Syslog clause, if
active.
2. Contact AudioCodes support,
which will want to collect addi-
tional data from the device
and perform a reset.
Stays 'Critical'
until reboot. A
'Clear' trap is
not sent.
After fatal
error
-
Configuration Error Alarm
Table 7-17: acBoardConfigurationError
Alarm acBoardConfigurationError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.2
Description The alarm is sent when the device's settings are invalid. The trap
contains a message stating, detailing, and explaining the invalid
setting.
Default Severity Critical
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable (56)
Severity Condition Text Corrective Action