EasyManua.ls Logo

AudioCodes Mediant 800 - Fatal Error Alarm; Configuration Error Alarm

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Fatal Error Alarm
Table 7-16: acBoardFatalError
Alarm acBoardFatalError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.1
Description The alarm is sent whenever a fatal device error occurs.
Default Severity Critical
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable (56)
Severity Condition Text Corrective Action
Critical Any fatal
error
"Board Fatal Error: A
run-time specific
string describing the
fatal error"
1. Capture the alarm inform-
ation and the Syslog clause, if
active.
2. Contact AudioCodes support,
which will want to collect addi-
tional data from the device
and perform a reset.
Stays 'Critical'
until reboot. A
'Clear' trap is
not sent.
After fatal
error
-
Configuration Error Alarm
Table 7-17: acBoardConfigurationError
Alarm acBoardConfigurationError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.2
Description The alarm is sent when the device's settings are invalid. The trap
contains a message stating, detailing, and explaining the invalid
setting.
Default Severity Critical
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable (56)
Severity Condition Text Corrective Action
- 115 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Related product manuals