CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acFloatingLicenseAlarm
Probable Cause communicationsProtocolError
Severity Condition Text
Corrective
Action
Warning An attempt was made to
configure a customized
Allocation Profile with values
that exceed the device's
capacity support based on
physical memory.
"Not enough
memory to
allocate for
'custom'
profile."
Configure an
Allocation
Profile within
the bounds of
the device's
capacity
support.
Network Alarms
This section describes alarms concerned with the network.
NTP Server Status Alarm
Table 7-36: acNTPServerStatusAlarm
Alarm acNTPServerStatusAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.71
Description The alarm is sent when the connection to the NTP server is lost.
Cleared when the connection is reestablished. Unset time (because
of no connection to NTP server) may result with functionality
degradation and failure in device. If the device receives no response
from the NTP server, it polls the NTP server for 10 minutes for a
response. If there is still no response after this duration, the device
declares the NTP server as unavailable, by sending this alarm. The
failed response could be due to incorrect configuration.
Default Severity Major
Event Type communicationsAlarm
Probable Cause communicationsSubsystemFailure
Severity Condition Text Corrective Action
Major No initial
communication to
Network Time
"NTP server alarm.
No connection to
NTP server."
Repair NTP
communication (the
NTP server is down or
- 140 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals