CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acBChannelAlarm
Type
Probable
Cause
degradedSignal
Alarm
Severity
Condition Text Corrective Action
Major B-channel service state changes to
'Out of Service' or 'Maintenance'
"B-Channel
Alarm. %s"
Corrective action
is not necessary
Clear B-channel status changes to 'In
Service'
"%s
additional
information"
-
D-Channel Status Alarm
The alarm is applicable only to digital PSTN interfaces.
Table 7-9: AcDChannelStatus
Alarm acDChannelStatus
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.37
Description The alarm is sent at the establishment, re-establishment or release of the
Link Access Protocol D-Channel (LAPD) link with its peer connection.
Default
Severity
Major
Source
Varbind
Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number (0 is the
first trunk)
Event Type communicationsAlarm
Probable
Cause
degradedSignal
Severity Condition Text
Corrective
Action
Major ISDN D-channel goes down (fails) "D-
Channel
-
- 103 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals