EasyManua.ls Logo

AudioCodes Mediant 800 - Analog Port Ground Fault Out-Of-Service Alarm

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acAnalogPortHighTemperature
automatically
disconnected.
down the analog
port and tries to
activate it again
later when the
device's
temperature
drops.
Cleared Temperature is
back to normal -
analog port is back
in service.
- -
Analog Port Ground Fault Out-of-Service Alarm
The alarm is applicable only to FXS interfaces.
Table 7-48: acAnalogPortGroundFaultOutOfService
Alarm acAnalogPortGroundFaultOutOfService
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.76
Default
Severity
Major / Clear
Source
Varbind Text
System#0/analogports#<n>, where n is the port number
Event Type physicalViolation
Probable
Cause
equipmentMalfunction (this alarm is sent when the FXS port is inactive
due to a ground fault)
Alarm Text Analog Port Ground Fault Out Of Service
Corrective
Action
No corrective action is required.
The device shuts down the port and tries to activate it again when
the relevant alarm is over.
- 151 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Related product manuals