EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acHTTPProxyServiceAlarm
Severity Condition Text Corrective Action
Major When
connection
to the
Upstream
Host is lost.
"HTTP Proxy
Upstream
Host IP:Port
(Host #n in
Upstream
Group name)
is OFFLINE"
1. Ping the host. If there is no
ping, contact your provider.
The probable reason is that
the host is down.
2. Ping between the host and the
device. If there is no ping, the
problem could be a net-
work/router issue.
3. Check that routing using the
device's (internal) routing table
is functioning correctly.
4. Contact AudioCodes support
center (sup-
port@audiocodes.com) and
send a syslog and network cap-
ture for this issue.
Cleared When
connection
to service is
available
again.
- -
Active Alarm Table Alarm
Table 7-45: acActiveAlarmTableOverflow
Alarm acActiveAlarmTableOverflow
OID 1.3.6.1.4.15003.9.10.1.21.2.0.12
Description The alarm is sent when an active alarm cannot be entered into the Active
Alarm table because the table is full.
Default
Severity
Major
Source
Varbind
Text
System#0<n>/AlarmManager#0
- 148 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals