CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
NGINX Process Not Running
Table 7-43: acNGINXPprocessIsNotRunningAlarm
Alarm acNGINXPprocessIsNotRunningAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.131
Description The alarm is sent when the device is restarted with an erroneous
NGINX configuration (i.e., after the alarm "NGINX Configuration is not
Valid" is sent (see above).
Alarm Source communicationsAlarm
Alarm Title NGINX process could not be started
Alarm Type alarmTrap
Probable Cause applicationSubsystemFailure
Severity Condition <text> Corrective Action
Major The device is
restarted with an
erroneous NGINX
configuration.
"NGINX process is
not running."
Correct the NGINX
Directives syntax (the
NGINX process will restart
automatically).
HTTP Proxy Service Alarm
Table 7-44: acHTTPProxyServiceAlarm
Alarm acHTTPProxyServiceAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.108
Description The alarm is sent when an HTTP host specified in the Upstream
Groups table is down. The trap is cleared when the host is back up.
Source Varbind
Text
System#0/HTTPProxyService#<num>
System#0/EMSService#<num>
Event Type communicationsAlarm
Probable Cause
■ Network issue (connection fail due to network/routing failure).
■ Host issue (host is down).
■ Device issue.
- 147 -