CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
NGINX Configuration is Invalid
Table 7-42: acNGINXConfigurationIsInvalidAlarm
Alarm acNGINXConfigurationIsInvalidAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.130
Description The alarm is sent when NGINX Directives Sets have been configured
with invalid syntax. NGINX continues to run with the previous, valid
configuration unless the device is restarted, in which case, the NGINX
process is stopped and the NGINX Process is not Running alarm is sent
(see below).
Alarm Title NGINX configuration is not valid
Alarm Source operationalViolation
Alarm Type alarmTrap
Probable Cause configurationOrCustomizationError
Severity Condition <text> Corrective Action
Minor NGINX Directives
Sets have been
configured with
invalid syntax.
"NGINX
Configuration file
is not valid."
Identify and resolve NGINX
Directives Sets syntax errors
to ensure an uninterrupted
HTTP Proxy service. You can
run CLI commands for
troubleshooting:
show network http-
proxy conf new: to
display the Directives Set
configuration that
generated the errors.
show network http-
proxy conf errors: to
display the errors
resulting from the
invalid Directives Set
configuration.
- 146 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals