EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
IPv6 Error Alarm
Table 7-41: acIPv6ErrorAlarm
Alarm acIPv6ErrorAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.53
Default
Severity
Critical
Source
Varbind
Text
System#0/Interfaces#<n>.
Event
Type
operationalViolation
Probable
Cause
communicationsProtocolError
Severity Condition Text
Corrective
Action
Critical Bad IPv6
address
(already
exists)
"IP interface alarm: IPv6 configuration failed, IPv6
will be disabled."
Find a
new
IPV6
address.
Reboot
the
device.
Note: The
alarm
remains in
Critical
severity
until the
device
reboots (a
Clear trap is
not sent).
HTTP Proxy NGINX Alarms
This section describes the alarms related to HTTP Proxy Services (NGINX).
- 145 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing