CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acACDThresholdAlarm
than the configured
Minor threshold (but
greater than the
Major threshold).
Cleared ACD is above the
configured Minor
threshold plus the
hysteresis.
- -
Network Effectiveness Ratio Threshold Alarm
Table 7-53: acNERThresholdAlarm
Alarm acNERThresholdAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.113
Description The NER (Network Effectiveness Ratio) measures the percentage of
successfully connected calls relative to the total number of seizures. The
alarm is sent when the configured NER minor and major thresholds are
crossed (configured in the Performance Profile table).
Source
Varbind
Text
The object for which the threshold is crossed can be one of the following:
PM_gwSBCNER
PM_gwSBCIPGroupNER
PM_gwSBCSRDNER
Alarm Text
Event Type Quality Of Service Alarm
Probable
Cause
The threshold has been crossed.
Severity Condition Text Corrective Action
Major NER is equal or less than
the configured Major
threshold.
"NER threshold
crossed."
Minor NER is equal or less than
the configured Minor
threshold (but greater
- 155 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals