CHAPTER6 Performance Monitoring
Mediant 800 SBC | SNMP Reference Guide
The tables in this section use check marks "√" and crosses "x" to indicate support for
the specific MIB property:
"G/C": gauge / counter
"Int": measured interval
"Val": value of gauge or counter
"Min": minimum gauge value
"Max": maximum gauge value
"Avg": average within the interval
"TbLT": percentage of interval time that value was below low threshold
"TbT": percentage of interval time that value was between low and high thresholds
"TaHT": percentage of interval time that value was above high threshold
"HT": configured or default high threshold
"LT": configured or default low threshold
Performance Monitoring MIBs for IP Network Interfaces
The following table lists the performance monitoring MIBs for IP network interfaces.
Table 6-1: Performance Monitoring MIBs for IP Network Interface
Performance Monitoring MIB
G
/
C
I
n
t
V
a
l
M
in
M
ax
A
v
g
Tb
LT
T
b
T
Ta
HT
H
T
L
T
MIB Name: acPMNetUtilKBytesTable
OID: 1.3.6.1.4.1.5003.10.11.2.31.1
Source Name: PM_NetUtilKBytes
Indicates the number of Kbytes
(1000 bytes) received and
transmitted on the interface (Index
0 is transmit; Index 1 is receive),
including those received in error,
from the beginning of the current
collection interval as indicated by
the time interval.
OVOC parameter name: Number of
Incoming / Outgoing Kbytes
High threshold:
acPMNetUtilsAttributesKBytesH
ighThreshold
(1.3.6.1.4.1.5003.10.11.1.33.1)
Low threshold:
acPMNetUtilsAttributesKBytesL
G 1
5
ü ü ü ü ü ü ü û û
- 33 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing